Measurement :Velocity, Acceleration RMS value, Peak value, Data hold, Max. & Min. value
Range Velocity : 200 mm/ : 0.5 to 199.9 mm/s, 7.87 inch/s : 0.02 to 7.87 inch/s
Frequency range :10 Hz to 1 KHz
Accuracy 😕 ( 5 % + 2 d ) reading , 160 Hz, 80 Hz. Calibration point : Velocity : 50 mm/s ( 160 Hz ), Acceleration : 50 ( 160 Hz ) Circuit :Exclusive microcomputer circuit.
Data hold :Freeze the desired reading Peak Measurement :To measure the peak value. Peak value = 1.414 RMS value
Memory :Maximum & Minimum value
Data output :RS 232 serial output, isolate
Power off :Auto shut off, saves battery life, or manual off by push button.